Skip to Content
Download Soil Risk Registry (PDF)
Forensic Soil Report

The Hidden Threat of Eddy very gravelly clay loam, 3 to 8 percent slopes for Homeowners in Schertz

Forensic LeadElias Thorne, P.E.
PublishedAugust 8, 2026
VerifiedGeological Registry v2026.1

Geological Profile: Schertz, TX

Soil TypeEddy
Plasticity (PI)19.0
Expansion Potential1.5% LEP
Risk ClassMODERATE

What is Eddy very gravelly clay loam, 3 to 8 percent slopes?

Eddy very gravelly clay loam, 3 to 8 percent slopes is a moderate clay soil formation common in Schertz. It is characterized by a high silica content that causes it to absorb water and swell volume by up to 1.5%. Engineers value it for agriculture but fear it for construction due to its "shrink-swell" volatility.

Why Schertz Foundations Fail

If you live in Central Schertz, or surrounding areas, your home is interacting with this critical geology. Unlike stable sandy loams, Eddy clay moves. Because of this severe movement, homeowners experiencing active structural settlement should immediately consult our Schertz Foundation Repair engineering team.

The defining metric is the Plasticity Index (PI) of 19.0. A PI between 15 and 25 indicates "Moderate" volatility. While not immediate, seasonal neglect (lack of watering) causes progressive differential settlement.

The "Active Zone" Depth

In Schertz, the "Active Zone"—where moisture levels fluctuate—extends 12-15 feet deep. Standard builder piers often stop at 8 feet. This mismatch is why we see repetitive failures in 78154.

"Homeowners in Schertz often pay for 'Standard Press Piles' that sit inside the active zone. When the Eddy very gravelly clay loam, 3 to 8 percent slopes moves, the pier moves with it."
- Elias Thorne, Lead Forensic Engineer

3 Signs of Eddy Soil Failure

  • Diagonal Shear Cracks: Extending from door/window corners (45-degree angles).
  • Friable Soil Gap: Soil pulling 1-2 inches away from the foundation perimeter in summer.
  • Sticking Doors: Specifically on the exterior walls relative to the center of the home.

Engineering Protocol: Correct vs. Incorrect

MethodSuitability for Eddy very gravelly clay loam, 3 to 8 percent slopesVerdict
Pressed Concrete PilingOften shallow (8-10ft); relies on friction in active clay.Avoid ❌
Steel Piers (E3000)Driven to absolute refusal (rock/shale) below active zone.Recommended ✅
Bell-Bottom PiersDrilled concrete; excellent stability but higher cost/mess.Viable Option

Apply these Findings to your Home

Request a Free Foundation Inspection for your specific street address.

Licensed TX P.E. Oversight (PE-88XXXX)

Neighborhood Watch

We are monitoring elevated PI readings in these areas:

Central Schertz

Unsure about your cracks?

Don't guess. Compare your symptoms against our forensic database or take the diagnostic quiz.